INSTALLATION AND USER INSTRUCTIONS
All instructions must be handed to user for safekeeping
Revision A - 08/05
Country(s) of destination - GB/IE
AFINA
CONVECTOR GAS FIRE
CK Fires Ltd. 1 Stour House, Clifford Park, Clifford Road,
Stratford Upon Avon, CV37 8HW
Tel : 01789 290 999 Fax : 01789 290 998
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - CONVECTOR GAS FIRE

INSTALLATION AND USER INSTRUCTIONSAll instructions must be handed to user for safekeepingRevision A - 08/05Country(s) of destination - GB/IEAFINACONVE

Pagina 2

GAS CONNECTIONRefit the burner tray into the firebox, fit the twoscrews through the locating holes in the tray legs,and tighten.Purge the gas supply t

Pagina 3 - IMPORTANT NNOTES

FUEL BED LAYOUT ((continued)3. Open the bag of 16 moulded coals. All of the coalsare the same. Take five coals and place them asshown. Care should be

Pagina 4

FUEL BED LAYOUT Pebble EEffect OOption1. Refer back to section 12.0 - Fuel bed layout (coaleffect option) and follow steps 1 and 2. The front stripand

Pagina 5

FUEL BED LAYOUT - ccontinued5. Finally, take the four remaining pebbles and placeat the back of the fuel matrix as shown. Once again, the pebbles may

Pagina 6 - Consstrucctional NNote:

OPERATING TTHE FFIRE ((continued)To decrease the setting to LOW, turn the control knob clockwise to the low setting.To turn to the PILOT position from

Pagina 7 - QUAANTITY DESCRIPTION

TESTING FOR SPILLAGEClose all doors and windows to the room containing the appliance. Let the fire run on HIGH for five minutes.Take a smoke match, li

Pagina 8

SERVICING ((continued)7. Check the area behind the firebox for rubble accumulation and remove. If debris is excessive, initiateremedial work on the fl

Pagina 9 - Dimension can

TROUBLESHOOTING GGUIDEFire ssparkss bbut ppilot ddoess nnot lligghtNo gas to fire, check isolators are open.Pipework blockage, clean out.Air not fully

Pagina 10 - Coal EEffect OOption

USER INSTTRUCTTIONSIMPORTANT NNOTESThe installation of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter)in

Pagina 11 - FUEL BED LAYOUT ((continued)

FIREFRONTThis fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow underthe firebed for the cor

Pagina 12 - Pebble EEffect OOption

INSTTALLATTION IINSTTRUCTTIONSPPrelimminnary NNotes BBefore IInnstallationnThis appliance is an Inset Live Fuel Effect appliance which provides radian

Pagina 13

FLUE SSPILLAGE MMONITORING SSYSTEMThis fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reas

Pagina 14

IMPORTANT NNOTESThis fire is an Inset Live Fuel Effect Gas Fire providing radiant warmth. It is designed to operate on Natural Gasonly. See Data Plate

Pagina 15

INSTALLATION RREQUIREMENTSThis appliance MUST NOT be installed into a room containing a bath or shower, or where steam may bepresent. The fire has bee

Pagina 16

SITE RREQUIREMENTS ((continued)This appliance required a natural draught flue system which may be one of the following;225mm x 225mm (9in x 9in) brick

Pagina 17 - TROUBLESHOOTING GGUIDE

DEBRIS CCOLLECTION SSPACEThe mounting depth of this appliance is 250mm. In accordance with BS 5871, minimum debris collection vol-umes are required be

Pagina 18 - USER INSTTRUCTTIONS

PREFABRICATED FFLUE BBOXES ((continued)Some flue boxes may require minor adaption when fitting the fire using the cable fixing kit.The firebox, base o

Pagina 19

PREPARING TTHE AAPPLIANCE ((continued)Knockout holes are provided in the rear and sides of thefirebox for use where concealed pipework is required.Whe

Pagina 20 - PAART NNO. ITEM

GAS SSUPPLY RROUTING ((continued)The gas pipe must be suitably protected where it passes through fireplace openings. Any sleeving should besealed to t